All calculators / Power & fuel
What size battery backup do I need?
A battery needs two numbers to match you: enough kWh to last the outage, and enough watts to run everything at once. This calculator gives both.
4.0 kWh battery, 1,000 W output
Running these loads for 1 day takes about 4.0 kWh. Look for a large power station (2–5 kWh, often expandable) that can deliver 1,000 W continuously and 2,500 W surge.
How we got there
| Refrigerator | 1,344 Wh/day | 700 W × 24 h × 8% of the time running |
|---|---|---|
| 20 LED bulbs | 1,200 Wh/day | 200 W × 6 h |
| Modem + router | 720 Wh/day | 30 W × 24 h |
| Phone chargers | 150 Wh/day | 50 W × 3 h |
| Energy per day | 3,410 Wh | |
| Energy for 1 day | 4,020 Wh | after inverter loss and usable depth (÷ 0.85) |
| Battery capacity needed | 4.0 kWh | |
| Continuous output needed | 980 W | everything on at once |
| Surge output needed | 2,480 W | when the refrigerator starts |
What to look for
- 2–5 kWh power stations: EcoFlow Delta Pro / Delta Pro 3, Jackery Explorer 2000 Plus, Anker SOLIX F3800, Bluetti AC300
Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.
Energy and power are different numbers
Energy, in kilowatt-hours, is how long the battery lasts. A refrigerator uses about 1.3 kWh a day because its compressor runs only part of the time. Power, in watts, is how much the inverter can deliver at once. The same refrigerator needs about 700 W while running and a 2,200 W surge to start.
The calculator adds up each load's watts × hours on × share of time it is drawing, divides by 0.85 for inverter loss and the reserve a battery keeps, and checks the running total and the largest surge against the inverter.
Which kind of battery
| Size | Type | Typical use |
|---|---|---|
| About 1 kWh | Portable power station | Fridge, internet and phones for half a day; CPAP for two nights |
| 2–5 kWh | Large or expandable power station | Fridge, freezer, internet, lights for a day; some run 240 V when paired |
| 10–15 kWh | Whole-home battery (installed) | Essentials for a day or more; with solar, indefinitely in summer |
| 20+ kWh | Two or more home batteries | Central AC or well pumps through a long outage |
For outages longer than two or three days at higher loads, a generator is usually cheaper per day. A battery's advantage is silence, no fuel, and instant switch-over.
Questions
How big a battery to run a refrigerator?
About 1.3 kWh a day for a typical refrigerator, so a 1 to 2 kWh power station covers a day. The inverter must handle about 2,200 W of start-up surge.
Can a battery run central air?
A whole-home battery can run a 3-ton AC with a soft starter, but it uses 15 to 20 kWh a day in summer. Plan two batteries or solar.
Battery or generator?
A battery for short outages, quiet and no fuel; a generator for long ones or heavy loads. Use the generator calculator with the same list to compare.
Sources
Method checked 2026-11-26. Full formulas on the methodology page.