All calculators / Heating & cooling
What size AC unit do I need?
Enter your house and climate. You get a tonnage, the cooling load behind it, and a warning if the nearest size would short-cycle.
Replacing an old unit? Check how old it is first.
3-ton central AC
Your estimated cooling load is 32,300 Btu/h (2.7 tons) for 2,000 sq ft in Zone 4A. Anything from 2.5 to 3 tons fits; 3 tons is the nearest standard size.
- This is an estimate, not an ACCA Manual J. For a whole-house system, ask the installer for a room-by-room Manual J before you sign.
How we got there
| Cooling design temperature | 92°F | 17°F above a 75°F room |
|---|---|---|
| Heat gain: walls | 2,750 Btu/h | |
| Heat gain: ceiling | 5,700 Btu/h | |
| Heat gain: windows | 13,280 Btu/h | conduction + sun through glass |
| Heat gain: people | 920 Btu/h | |
| Heat gain: appliances | 1,200 Btu/h | |
| Heat gain: air | 980 Btu/h | |
| Heat gain: humidity (latent) | 2,070 Btu/h | |
| Heat gain: ducts | 5,380 Btu/h | in an unconditioned attic or crawlspace |
| Cooling load | 32,300 Btu/h | 2.7 tons |
| Recommended size | 3 tons (36,000 Btu/h) | 112% of the load |
What to look for
- Any 3-ton condenser matched to its coil (AHRI-matched); 15.2+ SEER2 in the South, 13.4+ SEER2 in the North
- Examples: Goodman GLXS4BA, Carrier Performance 24SPA5, Trane XR16, Rheem RA16
Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.
Why tonnage per square foot is wrong
One ton of cooling is 12,000 Btu/h. The old rule of 400 to 600 sq ft per ton came from houses with no wall insulation and single-pane glass. A house built to the 2006 or later code in a mild climate often needs one ton per 900 to 1,200 sq ft.
Oversizing costs more than the bigger unit's price. A unit that cools the house in ten minutes shuts off before the coil has pulled water out of the air, so rooms feel cold and clammy, and the compressor wears from starting three or four times an hour.
The calculator adds up the heat that comes in through walls, ceiling and windows on a design-temperature day, plus people, appliances, air leaks and humidity. It then picks the smallest standard size that covers that load.
Standard sizes
| Tons | Btu/h | Often fits |
|---|---|---|
| 1.5 | 18,000 | Small, tight houses and condos |
| 2 | 24,000 | 1,000 to 1,600 sq ft |
| 2.5 | 30,000 | 1,300 to 2,000 sq ft |
| 3 | 36,000 | 1,600 to 2,400 sq ft |
| 3.5 | 42,000 | 2,000 to 2,800 sq ft |
| 4 | 48,000 | 2,400 to 3,200 sq ft |
| 5 | 60,000 | 3,000 sq ft and up |
The ranges overlap because climate and construction matter more than area. Use the calculator, not this table.
Replace or repair?
If the old condenser is more than 15 years old, plan for replacement rather than repair. The build date is in the serial number on the rating plate. Find out how old your current unit is on Serial Age Finder, then size the replacement here.
Common questions, worked out
Questions
Is a bigger AC unit better?
No. An oversized unit short-cycles: it reaches the thermostat setting before it has run long enough to dehumidify. You pay more for the unit, the house feels damp, and the compressor wears faster. ACCA Manual S allows cooling capacity up to 115% of the calculated load.
Does this replace a Manual J?
No. It uses the same physics with typical values for your type of house. Before you buy a whole-house system, ask the contractor for a room-by-room Manual J. If their answer is a full ton bigger than this one, ask why.
What if I'm replacing an AC that worked fine?
The old size is a useful check but not proof. Many existing systems are oversized, and new windows, insulation or air sealing since it was installed lower the load.
How many tons for 1,500 or 2,000 sq ft?
Typically 2 to 2.5 tons for 1,500 sq ft and 2.5 to 3 tons for 2,000 sq ft in a mixed climate with average insulation. Hot, sunny or leaky houses need more; see the worked answers below for each case.
How big of an AC unit do I need?
Big enough to cover the cooling load on a design-temperature day and no more than about 15% over it. For an average 2,000 sq ft house in a mixed climate that is about 2.7 tons of load, so a 3-ton unit. Hot, sunny or leaky houses need more.
Sources
Method checked 2026-11-26. Full formulas on the methodology page.