What size tankless water heater do I need?
Tankless heaters are sized by flow, not storage: how many gallons a minute of hot water you use at once, and how far the incoming water has to be heated in winter.
Replacing an old unit? Check how old it is first.
180,000 Btu/h gas tankless
You need about 4.7 gallons a minute of hot water with a 68°F rise in winter. That takes 167,000 Btu/h; a 180,000 Btu/h unit delivers about 5.0 gpm at that rise.
- Gas tankless units need a gas line sized for the full input (often 3/4 in) and their own venting. Check the gas meter can carry it with your other appliances.
How we got there
| Showers × 2 | 4.0 gpm | |
|---|---|---|
| Kitchen sink × 1 | 1.5 gpm | |
| Hot water flow at once | 4.7 gpm | 85% of tap flow is hot |
| Winter inlet water | 52°F | Zone 4A |
| Temperature rise | 68°F | to 120°F |
| Gas input needed | 167,000 Btu/h | at 95% efficiency |
| Recommended | 180,000 Btu/h unit |
What to look for
- 180,000 Btu/h condensing tankless
- Examples: Rinnai RU / RX series, Navien NPE-A2, Noritz NRCP
Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.
Flow × temperature rise
A tankless heater heats water as it flows. The size it needs is the flow of hot water at once, in gallons per minute, times the temperature rise: your setpoint minus the incoming water temperature. In Minnesota the incoming water can be 40°F in winter; in Florida, 70°F. The same two showers need almost twice the heater in the North.
Gas input in Btu/h = gpm × 500 × rise ÷ efficiency. Electric power in kW = gpm × rise ÷ 6.8.
Electric tankless and your panel
A whole-house electric tankless unit is one of the largest loads a home can have. A 27 kW unit draws about 113 A at 240 V, usually on three 40 A double-pole breakers. Many 200 A services can't add that without an upgrade. Before buying, have an electrician do a load calculation (NEC Article 220). In cold-water regions, a heat pump tank water heater often makes more sense.
Gas tankless installation
A 199,000 Btu/h unit usually needs a 3/4 in gas line, sized for its full input over the run length, and the gas meter has to carry it together with your furnace and range. Condensing units vent through PVC and need a condensate drain. Descale yearly where water is hard.
Replace or repair?
Tankless units typically last about 20 years with descaling. The build date is in the serial number on the rating plate. Find out how old your current unit is on Serial Age Finder, then size the replacement here.
Common questions, worked out
Questions
What size tankless water heater for a family of 4?
Usually a 180,000 to 199,000 Btu/h gas unit, enough for two showers and a sink at once in most of the country. Electric units that size draw 110 to 150 A. See the worked answer.
Will a tankless heater run two showers at once?
A 199,000 Btu/h gas unit runs two 2.0 gpm showers in all but the coldest regions. Electric units need 27 kW or more in the North to do the same.