All calculators / Heating & cooling
What size dehumidifier do I need?
Since 2019 dehumidifiers are rated at 65°F, so the same machine carries a smaller pint number than it did. Most sizing charts still use the old numbers. This one converts.
35-pint dehumidifier (2019 rating)
A very damp 1,000 sq ft basement needs about 12 pints/day on today's labels (17 on the old chart). Buy a medium (35 pint) unit; cool below-grade air cuts capacity, so this is one class up.
- In 2019 the DOE moved the test from 80°F to 65°F. A unit sold as "50 pint" today removes about what a 70-pint unit did before. Old charts and old reviews use the old number.
- Basements below about 60°F: pick a model rated to run cold (low-temperature defrost), and drain it to a floor drain or condensate pump so it can run unattended.
How we got there
| Area | 1,000 sq ft | |
|---|---|---|
| Condition | Very damp | |
| Moisture removal (old AHAM pints) | 17 pints/day | the pre-2019 chart |
| Same in 2019 DOE pints | 12 pints/day | how boxes are labeled today |
| Recommended class | medium (35 pint) | 2019 DOE rating |
What to look for
- 35-pint (2019 DOE) dehumidifier with a continuous-drain hose port or built-in pump
- Examples: Midea Cube / Midea 50-pint, Frigidaire 50-pint with pump, hOmeLabs 50-pint; for whole basements, AprilAire E070 or Santa Fe Compact70
Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.
The 2019 pint change
Dehumidifier capacity is the pints of water a unit removes in a day under test conditions. Until 2019 the test ran at 80°F and 60% relative humidity. The DOE moved it to 65°F, closer to a real basement, where the same machine removes less. A unit sold as 70 pints before 2019 is sold as about 50 pints now.
Many sizing charts, reviews and retailer guides still quote the old numbers. Comparing an old chart's "50 pints" with a new "50-pint" box overstates what you need by about 40%. The calculator starts from the AHAM chart in old pints and converts.
Basements and crawlspaces
Below 65°F a dehumidifier removes less than its label says, and below about 60°F the coil can frost. For basements and crawlspaces we go one size class up, and you should pick a model that is rated to run in the cold.
Drain it. A unit that relies on its bucket stops when the bucket is full. Use a hose to a floor drain or a model with a built-in pump.
Crawlspaces need sealing first: close the vents, lay a vapor barrier, then dehumidify. A crawlspace that is open to outside air can't be dried by any size of dehumidifier.
Common questions, worked out
Questions
What size dehumidifier for a 1,000 sq ft basement?
On today's labels, usually 35 pints if it is damp and 50 pints if it is wet or seeps. The old charts said 17 to 20 pints for the same space; that was in pre-2019 pints, and basements are colder than the test.
Is a bigger dehumidifier better?
Up to a point. A larger unit runs fewer hours and copes with summer peaks. It costs more to buy and uses more power when it runs. One class above the need is reasonable for basements.
What humidity should a basement be?
Below 60% relative humidity to stop mold, and around 45 to 50% is comfortable. A cheap hygrometer tells you whether the unit is keeping up.
How big of a dehumidifier do I need?
For most damp basements, a 35 or 50-pint unit on today's 2019 labels. Small rooms that only smell musty get by with a 20 to 22-pint unit; wet basements over 2,000 sq ft need a whole-basement unit.
Sources
Method checked 2026-11-26. Full formulas on the methodology page.