How Big Do I Need

All calculators / Heating & cooling

BTU calculator for a room

Enter the room and your climate. You get the cooling and heating Btu/h, the window AC size, and the electric heater size, with each part of the load listed.

More inputs

Calculated in your browser. Nothing you enter leaves this page.

6,500 Btu/h cooling · 6,000 Btu/h heating

A 400 sq ft room in Zone 4A needs about 6,500 Btu/h to cool on a 92°F day and 6,000 Btu/h (1.8 kW) to heat on a 15°F night.

  • Heating on the design night needs 6,000 Btu/h. Pick a hyper-heat / cold-climate model rated near full output at 15°F, or keep other heat in the room.

How we got there

Heating design temperature15°F55°F below a 70°F room
Heat loss: walls1,290 Btu/h
Heat loss: ceiling1,100 Btu/h
Heat loss: floor660 Btu/h
Heat loss: windows1,650 Btu/h
Heat loss: air1,270 Btu/h
Heating load6,000 Btu/hat the design temperature
Cooling design temperature92°F17°F above a 75°F room
Heat gain: walls630 Btu/h
Heat gain: ceiling1,140 Btu/h
Heat gain: windows2,660 Btu/hconduction + sun through glass
Heat gain: people460 Btu/h
Heat gain: appliances400 Btu/h
Heat gain: air200 Btu/h
Heat gain: humidity (latent)650 Btu/h
Cooling load6,100 Btu/h0.5 tons
As a window AC8,000 Btu/hnearest size
As an electric heater2.0 kW7 A at 240 V

What to look for

  • Single-zone 6,000 Btu/h ductless heat pump
  • DIY pre-charged: MRCOOL DIY 4th/5th Gen, Pioneer WYS/Diamante
  • Installed, cold climate: Mitsubishi M-Series Hyper-Heat (MSZ-FS / GL), Fujitsu Halcyon XLTH, Daikin Aurora

Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.

What a BTU number means

A Btu per hour is the rate heat moves. A window air conditioner rated 10,000 Btu/h removes that much heat from the room each hour at full speed; a 1,500 W space heater adds about 5,100 Btu/h (watts × 3.412).

Room needs differ more than floor area suggests. The calculator adds the heat that comes through the outside walls, ceiling and windows on a design-temperature day, plus people and appliances, then gives a heating number for the coldest design night as well.

Using the number

You are buyingUse
Window or portable ACThe cooling Btu/h; portable units need about 30% more than window units for the same room because their hose leaks heat
Mini-splitThe larger of cooling and heating, in a size listed in the mini-split calculator
Electric heaterThe heating Btu/h ÷ 3,412 = kW
Gas garage heaterThe heating Btu/h is output; divide by the heater's efficiency for input

Questions

How many BTU per square foot?

Rough charts use 20 to 25 Btu/h per square foot for cooling. Real rooms range from about 10 (shaded, insulated, mild climate) to 40 or more (uninsulated garage, west glass, hot climate). The calculator works from the room itself.

How many BTU to heat a 2-car garage?

An uninsulated 24 × 24 ft garage in a mixed climate needs roughly 12,000 to 20,000 Btu/h on the coldest night; insulated, about half. Set the space to garage to see your number.

Sources

Method checked 2026-11-26. Full formulas on the methodology page.