All calculators / Generator size calculator
What size generator for a 30 amp RV?
3,000 W portable generator
You need about 2,150 W running and 3,550 W at the moment the 13,500 Btu/h RV air conditioner starts. A generator with about 3,000 running watts (3,750 starting) covers that with headroom.
Assumes a 30 A RV running its 13,500 Btu/h roof air conditioner, fridge on electric, lights and a phone charger. Change the inputs.
30 amp RV generator size by load
| Running | Answer |
|---|---|
| Lights, fridge, phones (no AC) | 1,800 W portable generator |
| Roof AC, fridge, lights | 3,000 W portable generator |
| Roof AC + microwave | 4,500 W portable generator |
| Roof AC + coffee maker | 4,500 W portable generator |
| Roof AC, fridge on propane, lights | 3,000 W portable generator |
A 30 A RV service tops out at 3,600 W (30 A × 120 V); a bigger generator can't push more through the shore cord.
The roof AC sets the size
A 13,500 Btu/h roof air conditioner runs on about 1,500 W but needs around 2,900 W for a second to start the compressor. That surge is why a 2,000 W inverter generator often trips when the AC kicks on. A 3,000 W-class inverter starts it reliably; adding a soft-start kit to the AC (about $250) cuts the surge enough that many 2,200 W units can run it.
Run the microwave or coffee maker only while the AC compressor is off, or step up to a 4,000 W-class generator.
Run it for your house
The calculator below starts from the assumptions above. Change any input and the answer updates.
3,000 W portable generator
You need about 2,150 W running and 3,550 W at the moment the 13,500 Btu/h RV air conditioner starts. A generator with about 3,000 running watts (3,750 starting) covers that with headroom.
- Never back-feed through a dryer outlet. Connect through a transfer switch or interlock, and run the generator outdoors at least 20 ft from doors and windows: carbon monoxide kills.
How we got there
| 20 LED bulbs | 200 W running | 200 W to start |
|---|---|---|
| Phone chargers | 50 W running | 50 W to start |
| 13,500 Btu/h RV air conditioner | 1,500 W running | 2,900 W to start |
| RV fridge on electric | 400 W running | 600 W to start |
| All running together | 2,150 W | |
| Largest single start-up surge | +1,400 W | 13,500 Btu/h RV air conditioner, starting while everything else runs |
| Peak you must cover | 3,550 W | running total + the one largest surge |
| Headroom on running watts | 10% | so the engine isn't at full load for hours |
| Recommended size | 3,000 W running, 3,750 W starting |
What to look for
- About 3,000 running watts, inverter: Honda EU3000iS, Champion 3500 / 4500 Inverter, Westinghouse iGen4500
- Add: a transfer switch or panel interlock + inlet box, installed by an electrician
Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.
Questions
Will a 2,200 W generator run a 30 amp RV AC?
Usually not without a soft-start kit on the air conditioner. With one, many 2,200 W inverter generators can start a 13,500 Btu/h unit.
Do I need a 30 A or 50 A generator outlet?
A 30 A RV uses a TT-30 outlet. Most 3,000 W-class inverter generators have one.
Sources
Checked 2026-11-26. Full method on the methodology page.