All calculators / AC size calculator
What size AC unit for 1,500 square feet?
2.5-ton central AC
Your estimated cooling load is 25,600 Btu/h (2.1 tons) for 1,500 sq ft in Zone 4A. Anything from 2 to 2.5 tons fits; 2.5 tons is the nearest standard size.
Assumes a 1,500 sq ft one-story house with average insulation, ducts in the attic, 15% windows, climate zone 4A. Change the inputs.
1,500 sq ft by climate zone (average insulation)
| Climate | Answer |
|---|---|
| Zone 2A, hot humid (Houston) | 2.5-ton central AC |
| Zone 2B, hot dry (Phoenix) | 2.5-ton central AC |
| Zone 3A, warm humid (Atlanta) | 2.5-ton central AC |
| Zone 4A, mixed (Washington DC) | 2.5-ton central AC |
| Zone 5A, cool (Chicago) | 2-ton central AC |
| Zone 6A, cold (Minneapolis) | 2-ton central AC |
Why the answer ranges from 2 to 2.5 tons and beyond
The rule of thumb says 500 sq ft per ton, so 1,500 sq ft would be 3 tons. That rule fits a leaky 1970s house in Texas. A 1,500 sq ft house built to the current code in a mixed climate usually needs 2 to 2.5 tons, and a hot-dry desert house more.
The table holds the house the same and changes only the climate. Insulation, windows and duct location move the answer as much again; the calculator below takes all of them.
Run it for your house
The calculator below starts from the assumptions above. Change any input and the answer updates.
2.5-ton central AC
Your estimated cooling load is 25,600 Btu/h (2.1 tons) for 1,500 sq ft in Zone 4A. Anything from 2 to 2.5 tons fits; 2.5 tons is the nearest standard size.
- The nearest standard size is 117% of the load, above the usual 115% ceiling. Ask about a variable-speed (inverter) unit, which slows down instead of short-cycling.
- This is an estimate, not an ACCA Manual J. For a whole-house system, ask the installer for a room-by-room Manual J before you sign.
How we got there
| Cooling design temperature | 92°F | 17°F above a 75°F room |
|---|---|---|
| Heat gain: walls | 2,460 Btu/h | |
| Heat gain: ceiling | 4,280 Btu/h | |
| Heat gain: windows | 9,960 Btu/h | conduction + sun through glass |
| Heat gain: people | 920 Btu/h | |
| Heat gain: appliances | 1,200 Btu/h | |
| Heat gain: air | 730 Btu/h | |
| Heat gain: humidity (latent) | 1,750 Btu/h | |
| Heat gain: ducts | 4,260 Btu/h | in an unconditioned attic or crawlspace |
| Cooling load | 25,600 Btu/h | 2.1 tons |
| Recommended size | 2.5 tons (30,000 Btu/h) | 117% of the load |
What to look for
- Any 2.5-ton condenser matched to its coil (AHRI-matched); 15.2+ SEER2 in the South, 13.4+ SEER2 in the North
- Examples: Goodman GLXS4BA, Carrier Performance 24SPA5, Trane XR16, Rheem RA16
Examples only, not endorsements: model names checked 2026-11-26. Confirm the exact capacity on the spec sheet before you buy. We earn nothing from these.
Questions
Is 3 tons too big for 1,500 sq ft?
Often, yes, unless the house is old, leaky and in a hot climate. An oversized unit short-cycles and leaves the house clammy. Get a Manual J from the installer.
What about a two-story house?
Two stories with the same total area have less roof and more wall per square foot; the load is often slightly lower, but the upstairs runs hotter. Set floors to 2 in the calculator.